DVLS Petrochemical Analyzers
제품설명
@Applications & Benefits
1. Applications
1)Method
- ASTM D5134, ASTM D6729, ASTM D6730, ASTM D6733, ASTM D7900
2)Analysis of
- Individual hydrocarbons & group types , PIONA analysis of gasoline & blending components, Oxygenates
3)Application range
- Alkylate, Crude oil, Gasoline, Isomerate, Naphtha, Reformate/platformate, Pygas
2. Benefits
- High Quality GC Hardware
: All DHA Analyzers are based upon the Agilent GC configured with dedicated columns, injection ports and detectors.
- ASTM Compliance
: The DHA analyzers comply with the ASTM test methods D5134, D6729, D6730, D6733 and D7900 to determine hydrocarbons and oxygenates in light petroleum streams.
- Proven software platform
: The analyzers include the PetroReporter software for data processing and reporting of the properties of petroleum streams. PetroReporter is successfully used by a global installed base of leading oil refineries.
- Universal setup
: Analyst could also use PetroReporter to process and report data for SimDist, FAME and Gas Calculation applications in addition to DHA. They can use the universal software for various applications.
- High level of Automation
: PetroReporter automates the settings per sample type to provide a correct sample identification. User-friendly editors can be used to customize your settings.
- Accurate characterization of crude oils
: To improve the boiling point characterization of crude oils the DVLS PetroReporter merges High Temp SimDist with the DHA data.
- Application Guarantee
: Each analyzer is tested according to the in-house testing procedures to check the system performance and to verify the analyzer specification by a reference sample test. Factory Acceptance Test will be scheduled upon request.
@Configuration & Option
The DHA configuration is based on the Agilent Gas Chromatograph configured for a test method with the required hardware and software components (based on the Agilent 8890 GC)
- Flame Ionization Detector (FID) with high scanning rate
- Split/Splitless injection port to split the sample for maximum detection and load ability of the column
- Cryogenic mode (N2 or CO2)
- 50 or 100 meter DHA analytical column
- Calibration, reference or quality control samples
- PetroReporter software
: a universal software tool that automates data processing of petroleum samples. After data processing PetroReporter creates the required DHA reports. Some examples are: Chromatogram plot of the peak labels over a user selectable time interval, Individual hydrocarbons & group types, Oxygenates, PIONA report, TBP distribution, Properties summary of Bromine Number, Gross and Nett Heat of Combustion of liquid, Reid Vapor Pressure, RON and MON values, Specific Gravity.